summaryrefslogtreecommitdiffstats
path: root/drivers/spmi/Kconfig
diff options
context:
space:
mode:
authorArınç ÜNAL <arinc.unal@arinc9.com>2024-03-14 12:33:41 +0300
committerPaolo Abeni <pabeni@redhat.com>2024-03-21 12:03:00 +0100
commite8bf353577f382c7066c661fed41b2adc0fc7c40 (patch)
tree061235682b685714e44a2eaa2886f2c3fdcc507e /drivers/spmi/Kconfig
parent3201de46a2013293abe28caa46aa0387864d7cf7 (diff)
downloadlinux-stable-e8bf353577f382c7066c661fed41b2adc0fc7c40.tar.gz
linux-stable-e8bf353577f382c7066c661fed41b2adc0fc7c40.tar.bz2
linux-stable-e8bf353577f382c7066c661fed41b2adc0fc7c40.zip
net: dsa: mt7530: fix link-local frames that ingress vlan filtering ports
Whether VLAN-aware or not, on every VID VLAN table entry that has the CPU port as a member of it, frames are set to egress the CPU port with the VLAN tag stacked. This is so that VLAN tags can be appended after hardware special tag (called DSA tag in the context of Linux drivers). For user ports on a VLAN-unaware bridge, frame ingressing the user port egresses CPU port with only the special tag. For user ports on a VLAN-aware bridge, frame ingressing the user port egresses CPU port with the special tag and the VLAN tag. This causes issues with link-local frames, specifically BPDUs, because the software expects to receive them VLAN-untagged. There are two options to make link-local frames egress untagged. Setting CONSISTENT or UNTAGGED on the EG_TAG bits on the relevant register. CONSISTENT means frames egress exactly as they ingress. That means egressing with the VLAN tag they had at ingress or egressing untagged if they ingressed untagged. Although link-local frames are not supposed to be transmitted VLAN-tagged, if they are done so, when egressing through a CPU port, the special tag field will be broken. BPDU egresses CPU port with VLAN tag egressing stacked, received on software: 00:01:25.104821 AF Unknown (382365846), length 106: | STAG | | VLAN | 0x0000: 0000 6c27 614d 4143 0001 0000 8100 0001 ..l'aMAC........ 0x0010: 0026 4242 0300 0000 0000 0000 6c27 614d .&BB........l'aM 0x0020: 4143 0000 0000 0000 6c27 614d 4143 0000 AC......l'aMAC.. 0x0030: 0000 1400 0200 0f00 0000 0000 0000 0000 ................ BPDU egresses CPU port with VLAN tag egressing untagged, received on software: 00:23:56.628708 AF Unknown (25215488), length 64: | STAG | 0x0000: 0000 6c27 614d 4143 0001 0000 0026 4242 ..l'aMAC.....&BB 0x0010: 0300 0000 0000 0000 6c27 614d 4143 0000 ........l'aMAC.. 0x0020: 0000 0000 6c27 614d 4143 0000 0000 1400 ....l'aMAC...... 0x0030: 0200 0f00 0000 0000 0000 0000 ............ BPDU egresses CPU port with VLAN tag egressing tagged, received on software: 00:01:34.311963 AF Unknown (25215488), length 64: | Mess | 0x0000: 0000 6c27 614d 4143 0001 0001 0026 4242 ..l'aMAC.....&BB 0x0010: 0300 0000 0000 0000 6c27 614d 4143 0000 ........l'aMAC.. 0x0020: 0000 0000 6c27 614d 4143 0000 0000 1400 ....l'aMAC...... 0x0030: 0200 0f00 0000 0000 0000 0000 ............ To prevent confusing the software, force the frame to egress UNTAGGED instead of CONSISTENT. This way, frames can't possibly be received TAGGED by software which would have the special tag field broken. VLAN Tag Egress Procedure For all frames, one of these options set the earliest in this order will apply to the frame: - EG_TAG in certain registers for certain frames. This will apply to frame with matching MAC DA or EtherType. - EG_TAG in the address table. This will apply to frame at its incoming port. - EG_TAG in the PVC register. This will apply to frame at its incoming port. - EG_CON and [EG_TAG per port] in the VLAN table. This will apply to frame at its outgoing port. - EG_TAG in the PCR register. This will apply to frame at its outgoing port. EG_TAG in certain registers for certain frames: PPPoE Discovery_ARP/RARP: PPP_EG_TAG and ARP_EG_TAG in the APC register. IGMP_MLD: IGMP_EG_TAG and MLD_EG_TAG in the IMC register. BPDU and PAE: BPDU_EG_TAG and PAE_EG_TAG in the BPC register. REV_01 and REV_02: R01_EG_TAG and R02_EG_TAG in the RGAC1 register. REV_03 and REV_0E: R03_EG_TAG and R0E_EG_TAG in the RGAC2 register. REV_10 and REV_20: R10_EG_TAG and R20_EG_TAG in the RGAC3 register. REV_21 and REV_UN: R21_EG_TAG and RUN_EG_TAG in the RGAC4 register. With this change, it can be observed that a bridge interface with stp_state and vlan_filtering enabled will properly block ports now. Fixes: b8f126a8d543 ("net-next: dsa: add dsa support for Mediatek MT7530 switch") Signed-off-by: Arınç ÜNAL <arinc.unal@arinc9.com> Signed-off-by: Paolo Abeni <pabeni@redhat.com>
Diffstat (limited to 'drivers/spmi/Kconfig')
0 files changed, 0 insertions, 0 deletions